Adtran 3060 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Adtran 3060. ADTRAN 3060 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 30
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1Section 61182007L1-5, Issue 161182007L1-5A
Section 61182007L1-5A
Issue 1, June 2001
Total Access
®
3010 LTU
High-bit-rate Digital Subscriber Line
Transceiver Unit for the Central Office
Installation and Maintenance
CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION .................................................................. 2
3. OPERATION ........................................................................ 3
4. HDSL SYSTEM TESTING .................................................. 4
5. SCU CONTROL PORT OPERATION (HDSL) ................. 5
6. HDSL DEPLOYMENT GUIDELINES ............................. 17
7. MAINTENANCE ............................................................... 17
8. PRODUCT SPECIFICATIONS ......................................... 17
9. WARRANTY AND CUSTOMER SERVICE ................... 17
Appendix A. HDSL H-LSS Circuit Configuration and Turnup
for G.703 Fed Systems .................................... A-1
Appendix B. HDSL H-LSS Circuit Configuration and Turnup
for DS3-Fed Systems ...................................... B-1
FIGURES
Figure 1. ADTRAN Total Access 3010 LTU ........................... 1
Figure 2. LTU Edge Connector Wiring .................................... 2
Figure 3. LTU Span Powering Diagram ................................... 4
Figure 4. HDSL Loopbacks ...................................................... 5
Figure 5. RS-232 (DB-9) Pin Assignments .............................. 5
Figure 6. Logon Screen ............................................................. 7
Figure 7. Total Access Screen ................................................... 7
Figure 8. Access Module Menus Screen................................... 8
Figure 9. HDSL Main Menu Screen ......................................... 9
Figure 10. Configuration Screen ................................................. 9
Figure 11. Provisioning Screen ................................................. 10
Figure 12. Network Source Screen ........................................... 10
Figure 13. Status Screen ............................................................ 11
Figure 14. REG #1 Status Screen .............................................. 11
Figure 15. Alarms Screen .......................................................... 12
Figure 16. Test Screen ............................................................... 13
Figure 17. Performance History Screen .................................... 13
Figure 18. Protection Configuration Screen – Main ................ 14
Figure 19. Protection Configuration Screen – Auxiliary ......... 14
Figure 20. Set Circuit ID Screen ............................................... 16
Figure 21. Alarm Option Screen ............................................... 17
TABLES
Table 1. Faceplate LED Indicators .......................................... 3
Table 2. Screen Abbreviations ................................................. 6
Table 3. LP1 and LP2 Guidellines ......................................... 12
Table 4. Protection Configuration Option Settings ............... 15
Table 5. Total Access 3010 LTU Specifications................... 18
Table B-1. Faceplate LED Indicator ....................................... B-2
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
1. GENERAL
The ADTRAN Total Access 3010 HDSL Transceiver
Unit for the Central Office (LTU), part number
1182007L1, is the Central Office (CO) unit used to
deploy an HDSL E1 circuit using 4-wire metallic
facilities. See Figure 1.
The E1 input signal is supplied from the network via
individual G.703 lines or an E3 multiplexer. The
HDSL signals are provided to the local loop. The
Total Access 3010 LTU works in conjunction with the
ADTRAN NTU and REG to provide an E1 service up
to 9.4 km on the local loop.
The LTU works with multiple list versions of the
HDSL unit Remote end (NTU) and HDSL Range
Extender (REG) as listed below:
1245043Lx Low Voltage T400 REG
1245031Lx, Low Voltage T200 NTU
1245033Lx, Nx64 NTU
1245044L3, 4th Gen - T400 NTU
1245035Lx, 5th Gen - T200 NTU
The Total Access 3010 LTU can be deployed in
circuits consisting of one LTU and one NTU or in a
protection configuration requiring two LTUs and two
NTUs. When deployment requires the HDSL Range
Extender (REG), this LTU can be deployed with one
or two REGs and one NTU.
Figure 1. ADTRAN Total Access 3010 LTU
TX
M
O
N
E
Q
RX
TX
RX
ACT
A
P
S
GRN = NORM
YEL = MAN
LP1
TST
G703
PWR
LP2
ALM
LT U
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - Installation and Maintenance

1Section 61182007L1-5, Issue 161182007L1-5ASection 61182007L1-5AIssue 1, June 2001Total Access® 3010 LTUHigh-bit-rate Digital Subscriber LineTransceiv

Página 2 - C A U T I O N !

10 Section 61182007L1-5, Issue 1 61182007L1-5AThe Provisioning Screen, as illustrated in Figure 11,displays current provisioning settings and allows f

Página 3

11Section 61182007L1-5, Issue 161182007L1-5AThe Status Screen, illustrated in Figure 13, providesquick access to status information for both the LTUan

Página 4

12 Section 61182007L1-5, Issue 1 61182007L1-5APredicting performance based upon signal qualityvaries with each loop. Generally, a noise margin of 0or

Página 5

13Section 61182007L1-5, Issue 161182007L1-5AAt each 15-minute interval, the performanceinformation is transferred to the 15-minuteperformance data reg

Página 6

14 Section 61182007L1-5, Issue 1 61182007L1-5AThe Protection Configuration Screen - Main,illustrated in Figure 18, displays the current settingsfor Pr

Página 7

15Section 61182007L1-5, Issue 161182007L1-5ATable 4. Protection Configuration Option SettingssnoitpOnoitcetorPsgnitteSnoitpircseDedoMnoitcetorPotuA .

Página 8

16 Section 61182007L1-5, Issue 1 61182007L1-5ASystem Current Status are also displayed beneath theCurrent Settings summary. The Current SystemStatus

Página 9

17Section 61182007L1-5, Issue 161182007L1-5AFigure 21 illustrates the Alarm Options Screen. Thisoption allows the user to first set a 15-minutethresho

Página 10

18 Section 61182007L1-5, Issue 1 61182007L1-5ATable 5. Total Access 3000 LTU SpecificationsLoop InterfaceModulation Type ...

Página 11

19Section 61182007L1-5, Issue 161182007L1-5A9. WARRANTY AND CUSTOMER SERVICEADTRAN will replace or repair this product withinfive (5) years from the

Página 12 - 0<nigraMdeRytilauQpooLrooP

2 Section 61182007L1-5, Issue 1 61182007L1-5AC A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGEOR DECREASE IN RELIABILITY.HANDLING PRECAUTIONS REQUIRED.T

Página 13

20 Section 61182007L1-5, Issue 1 61182007L1-5A

Página 14

61182007L1-5A Section 61182007L1-5, Issue 1 A-1Appendix AHDSL H-LSS Circuit Configuration and Turnupfor G.703 Fed SystemsIntroductionThis section prov

Página 15

A-2 Section 61182007L1-5, Issue 1 61182007L1-5AIf this is an initial installation, the units will requireprovisioning to appropriately configure them

Página 16

61182007L1-5A Section 61182007L1-5, Issue 1 A-34.1.4 Upon provisioning of the NTUs,the faceplate LEDs should read asshown in Table 1.NOTEThe condition

Página 17

A-4 Section 61182007L1-5, Issue 1 61182007L1-5A

Página 18 - 8. PRODUCT SPECIFICATIONS

61182007L1-5A Section 61182007L1-5, Issue 1 B-1Appendix BHDSL H-LSS Circuit Configuration and Turnupfor DS3-Fed Systems1. UNPACK AND INSPECT THE THE

Página 19

B-2 Section 61182007L1-5, Issue 1 61182007L1-5ANOTEOnly one DS3 MUX is required for any datacircuit to be operational. Two modules are usedfor ele

Página 20

61182007L1-5A Section 61182007L1-5, Issue 1 B-33. INSTALL THE LTUThe Total Access 3010 LTU delivers an E1 signalover an HDSL local loop. The local lo

Página 21 - Appendix A

B-4 Section 61182007L1-5, Issue 1 61182007L1-5A3.2.5 From the provisioning menu of theAUX circuit, reset the AUX unit toOOS-M.3.2.6 Logoff the system.

Página 22 - Remote Housing

61182007L1-5A Section 61182007L1-5, Issue 1 B-5NOTEEnsure that data has been removed from theAUX circuit before proceeding with the nexts

Página 23

3Section 61182007L1-5, Issue 161182007L1-5A3. OPERATIONPowering OptionsThe unit features automatic sensing based on thecurrent load detected on the H

Página 24

B-6 Section 61182007L1-5, Issue 1 61182007L1-5A

Página 25 - Appendix B

4 Section 61182007L1-5, Issue 1 61182007L1-5AStatus ModeAfter selecting the LTU from the SCU, the displayenters Status mode. It alternately displays l

Página 26

5Section 61182007L1-5, Issue 161182007L1-5AREG LoopbackThe REG HDSL transceivers are looped back towardthe LTU. This loopback enables a complete chec

Página 27

6 Section 61182007L1-5, Issue 1 61182007L1-5AMany portable personal computers use power-savingprograms that are known to interfere with applicationsru

Página 28

7Section 61182007L1-5, Issue 161182007L1-5AFigure 6. Logon ScreenShelf: 77 Total Access System 04/07/01 15:44Unac

Página 29

8 Section 61182007L1-5, Issue 1 61182007L1-5AFrom the Total Access System Screen, select AccessModules by typing the number corresponding to theoption

Página 30

9Section 61182007L1-5, Issue 161182007L1-5AThis will display the ADTRAN HDSL Main Menu asillustrated in Figure 9.From the ADTRAN HDSL Main Menu, the f

Modelos relacionados 3010

Comentários a estes Manuais

Sem comentários