Chapter 5. Configuration Menu
61202156L1-1 TDU 120e User Manual 5-17
“O” INHIB
The Nx interface will detect an uninterrupted string of zeros
(0s) being transmitted toward the network. If 0s are transmit-
ted for >1 second, the TDU 120e will force 1s.
Choices: On or Off
INBAND MODE
The Nx56/64 port is capable of providing an inband commu-
nications channel (for T-Watch and SNMP) between units.
This is accomplished by using 8 kbps of the first DS0
assigned to that particular Nx56/64 port. If in 56 K mode, no
data bandwidth will be used. Inband must also be enabled at
the destination port.
Choices: On or Off, On Demand
TX CLK SOURCE
Controls the source of the clock used by the TDU 120e to
accept transmit data from the DTE.
Default: Internal.
If the application requires that the DTE device provide the
clock with the transmit data, the E
XTERNAL
setting is used.
Choices: Internal, External
This table indicates conditions which cause the Port Control
Signals to be deactivated.
Table 5-1. Normal Mode of Operation
RTS V.54
Loopback
511 TST
ON
Self Test
Active
Netwk Test
Active
No DS0
Mapped
Network
Alarm
CTS Follows OFF OFF OFF OFF OFF
DCD OFF OFF OFF
DSR OFF OFF OFF OFF
Where “— = dont care
Force On = On under all conditions