ADTRAN 4202023L2 Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
Smart 16e Shelf User Manual Installation of Controller Card
64202023L5-1B © 2004 ADTRAN, Inc. 25
Alarm Connections
The terminal strips located on the back of the Smart 16e Shelf controller card are labeled ALARM. They
are used for audio or visual alarm indicators provided by the user. The top two terminals are a set and the
bottom two are a set. The terminals are activated together when the cards inserted in the designated slots
encounter an alarm condition such as primary link failure.
To verify operation of the terminal strip, measure the impedance across each set. The impedance should be
open when the shelf is not in alarm and shorted (approximately 0.6 ohm) when in alarm. The two alarm
sets operate identically and should have the same impedance. The power specifications for any alarms used
are NEC Class 2 and 48 VDC @ 500 mA maximum. Figure 2 shows the alarm connection.
Figure 2. Alarm Connection
Power
Source
Power
Source
A
larm Relay
D
T
E
/
D
C
E
E
I
A
2
3
2
SMART 16e
AC
POWER I/F
ALARM
NO
COM
NO
COM
F1
F2
#1
#2
5A
250V
3AG
115VAC/60 HZ
2.5 AMP
L
A
N
10 BASE T
FUSE
FUSE
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 55 56

Comentários a estes Manuais

Sem comentários