ADTRAN QDFR Unit Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Redes ADTRAN QDFR Unit. ADTRAN QDFR Unit Unit installation Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 48
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Quad Fiber Remote (QDFR) Unit
Installation and Maintenance Practice
Document Number: 61181307L7-5E
CLEI: M3M1100B _ _
July 2006
QDFR
OPTICS
DS1 1
DS1 2
DS1 3
DS1 4
TEST
T
E
R
M
(R
)
M
O
N
(G
)
1
1
8
1
30
7
L
7
C
H
S
E
L
E
C
T
L
B
K
LBK
N
E
N
D
(Y
)
F
E
N
G
(G
)
®
Vista de página 0
1 2 3 4 5 6 ... 47 48

Resumo do Conteúdo

Página 1 - Quad Fiber Remote (QDFR) Unit

Quad Fiber Remote (QDFR) UnitInstallation and Maintenance PracticeDocument Number: 61181307L7-5ECLEI: M3M1100B _ _July 2006QDFROPTICSDS1 1DS1 2DS1 3DS

Página 2 - To the Holder of the Document

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice2 61181307L7-5EFeaturesThe QDFR provides the following features:• Software provisio

Página 3 - Conventions

Installation61181307L7-5E 3INSTALLATIONAfter unpacking the QDFR, inspect it for damage. If damage has occurred, file a claim with the carrier then con

Página 4 - Training

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice4 61181307L7-5EFront Panel PushbuttonsThe QDFR has two pushbuttons located on the f

Página 5 - Contents

Loop Connections61181307L7-5E 5LOOP CONNECTIONSThe T1 loop connections are made through four RJ-48C type connectors. For each connector, transmit tip

Página 6

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice6 61181307L7-5EPROVISIONINGThe QDFR provides the ability to change provisioning opt

Página 7 - 61181307L7-5E vii

Menu Structure61181307L7-5E 7MENU STRUCTUREThe menu structure for the QDFR is a layered menu tree. Each layer of the menu tree is displayed as a menu

Página 8

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice8 61181307L7-5EMENU DESCRIPTIONSThe QDFR Main Menu (Figure 4) is the access point t

Página 9 - Quad Fiber Remote Unit

Menu Descriptions61181307L7-5E 9QDF Unit Information ScreenThe QDF Unit Information screen (see Figure 5) is a read-only display that identifies the Q

Página 10 - Compliance

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice10 61181307L7-5EProvisioning MenuThe Provisioning menu (Figure 6) is used to make p

Página 11 - Front Panel LEDs

Menu Descriptions61181307L7-5E 11Status ScreenThe Status screen (Figure 7) provides information regarding the status of the QDFR.Figure 7. Status Scr

Página 12 - Front Panel Pushbuttons

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practiceii 61181307L7-5EFront MatterTrademarksAny brand names and product names included in

Página 13 - LOOP CONNECTIONS

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice12 61181307L7-5ELoopback and Test Commands MenuLoopback and Test Commands menu (Fig

Página 14 - PROVISIONING

Menu Descriptions61181307L7-5E 13Test Jack Configuration ScreenThe Test Jack Configuration screen (Figure 11) controls the test jack, which is found o

Página 15 - MENU NAVIGATION

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice14 61181307L7-5EBERT Test ScreenThe Channel # BERT Test screen (Figure 12) performs

Página 16 - MENU DESCRIPTIONS

Menu Descriptions61181307L7-5E 15• Enter Test Timeout – This option displays the Network Timeout screen (Figure 14). The timeout can run for a specifi

Página 17 - 61181307L7-5E 9

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice16 61181307L7-5ESelf-Tests ScreenSelecting Self-Tests performs tests of the QDFC an

Página 18 - 10 61181307L7-5E

Menu Descriptions61181307L7-5E 17Performance History Channel # MenuThe Performance History Channel # menu (Figure 18) displays the performance of a sp

Página 19 - 61181307L7-5E 11

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice18 61181307L7-5EThe Channel Performance History of the DSX-1 Rx from the network is

Página 20 - 12 61181307L7-5E

Menu Descriptions61181307L7-5E 19Scratch Pad, Circuit ID MenuThe Scratch Pad, Circuit ID menu (Figure 22) is used to give each circuit a circuit ID na

Página 21 - 61181307L7-5E 13

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice20 61181307L7-5EAlarm History MenuThe Alarm History menu (Figure 23) provides the o

Página 22 - 14 61181307L7-5E

Menu Descriptions61181307L7-5E 21Channel T1 Threshold Alarm History ScreenAn individual Channel T1 Threshold Alarm History screen (Figure 25) provides

Página 23 - 61181307L7-5E 15

61181307L7-5E iiiRevision HistoryConventionsThe following typographical conventions are used in this document:This font indicates a cross-reference li

Página 24 - 16 61181307L7-5E

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice22 61181307L7-5ETroubleshooting MenuThe Troubleshooting menu (Figure 27) compiles i

Página 25 - 61181307L7-5E 17

Menu Descriptions61181307L7-5E 23Clear PM and Alarm Histories OptionSelecting the Clear PM and Alarm Histories option from the QDF Main menu, displays

Página 26 - 18 61181307L7-5E

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice24 61181307L7-5ESystem PM/Screen Report MenuSystem PM/Screen Report menu (Figure 30

Página 27 - 61181307L7-5E 19

Menu Descriptions61181307L7-5E 25Download QDFR via Y-Modem MenuThe Download QDFR via Y-Modem menu (Figure 31) initiates a Y-Modem file transfer from t

Página 28 - 20 61181307L7-5E

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice26 61181307L7-5EVirtual Terminal ControlThe Virtual Control screen allows control o

Página 29 - 61181307L7-5E 21

Maintenance61181307L7-5E 27MAINTENANCEThe QDFR does not require routine maintenance for normal operation. In case of equipment malfunction, use the re

Página 30 - 22 61181307L7-5E

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice28 61181307L7-5EThis page is intentionally blank.

Página 31 - 61181307L7-5E 23

61181307L7-5E A-1 Appendix AQDFR LoopbacksFIBER LINE UNIT MAINTENANCE MODESThis appendix describes operation of the optical fiber system with regard t

Página 32 - 24 61181307L7-5E

Quad Fiber Remote (QDFR) Unit Installation and Maintenance PracticeA-2 61181307L7-5ELoopback Control CodesA summary of control sequences is given in T

Página 33 - 61181307L7-5E 25

Fiber Line Unit Maintenance Modes61181307L7-5E A-31. Units must be armed with 11000b or FF48h before this code will work. 2. Loopback and error inject

Página 34 - CTRL+X to

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practiceiv 61181307L7-5ETrainingADTRAN offers training courses on our products. These cours

Página 35 - SPECIFICATIONS

Quad Fiber Remote (QDFR) Unit Installation and Maintenance PracticeA-4 61181307L7-5EThis page is intentionally blank.

Página 36 - 28 61181307L7-5E

61181307L7-5E B-1 Appendix BRear Panel DS1 Test AccessGENERALFigure B-1 through Figure B-3 provides a graphical description of the test jack functiona

Página 37 - QDFR Loopbacks

Quad Fiber Remote (QDFR) Unit Installation and Maintenance PracticeB-2 61181307L7-5EMONITOR MODEMonitor Tx to CustomerThe Rx of the monitor BERT recei

Página 38 - Loopback Control Codes

Monitor Mode61181307L7-5E B-3Monitor Rx from CustomerThe Rx of the monitor BERT receives data from the RX point of the test jack, Figure B-2. This mon

Página 39

Quad Fiber Remote (QDFR) Unit Installation and Maintenance PracticeB-4 61181307L7-5ETER MINATE MODEIntrusive Tx to Customer and Rx from CustomerNOTETh

Página 40 - A-4 61181307L7-5E

Terminate Mode61181307L7-5E B-5Intrusive Tx to Network and Rx from NetworkNOTEThis is an intrusive test and the original data path will be dis-rupted.

Página 41 - Rear Panel DS1 Test Access

Quad Fiber Remote (QDFR) Unit Installation and Maintenance PracticeB-6 61181307L7-5EThis page is intentionally blank.

Página 42 - Monitor Tx to Customer

61181307L7-5E C-1 Appendix CWarrantyWARRANTY AND CUSTOMER SERVICEADTRAN will replace or repair this product within the warranty period if it does not

Página 43 - Monitor Rx from Customer

Carrier Networks Division901 Explorer Blvd.Huntsville, AL 35806®

Página 44 - TER MINATE MODE

61181307L7-5E v ContentsGeneral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 45 - 61181307L7-5E B-5

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practicevi 61181307L7-5EChannel T1 Threshold Alarm History Screen . . . . . . . . . . . .

Página 46 - B-6 61181307L7-5E

Contents61181307L7-5E viiFiguresFigure 1. QDFR Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 47 - Warranty

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practiceviii 61181307L7-5ETablesTable 1. Compliance Codes . . . . . . . . . . . . . . . .

Página 48 - Huntsville, AL 35806

61181307L7-5E 1 Quad Fiber Remote UnitGENERALThis practice is an installation and maintenance guide for the ADTRAN Quad Fiber Remote (QDFR) unit. The