ADTRAN TSU 120 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes ADTRAN TSU 120. ADTRAN TSU 120 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 142
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - User Manual

TSU 120 & 120eUser ManualPart Number1202129L11202129L2December 200161202129L1-1D

Página 2 - Trademarks:

xFederal Communications Commission Radio Frequency Interference StatementThis equipment has been tested and found to comply with the limits for a Clas

Página 3 - Safety Instructions

Chapter 7. Test Menu7-8 TSU 120 User Manual 61202129L1-1The self-test consists of the following tests:A test pattern is sent from the controller throu

Página 4

Chapter 7. Test Menu61202129L1-1 TSU 120 User Manual 7-9Port Test Menu Items for 0.1 Nx56/640.1 Nx56/64 is the base Nx interface. It offers the follow

Página 5

Chapter 7. Test Menu7-10 TSU 120 User Manual 61202129L1-1DBU Loopback (TSU 120e only)DBU Test (TSU 120e only)This selection is used to force a backup

Página 6

61202129L1-1 TSU 120 User Manual 8-1Chapter 8Telnet/Terminal MenusMAIN MENUThe TELNET/TERMINAL MAIN MENU is the first menu displayed after the TELNET/

Página 7

Chapter 8. Telnet/Terminal Menus8-2 TSU 120 User Manual 61202129L1-1Status, Config, Util, and Test Menu OptionsThese menu items can access the same mo

Página 8 - Service Type REN/SOC FIC USOC

Chapter 8. Telnet/Terminal Menus61202129L1-1 TSU 120 User Manual 8-3You can use the ARROW KEYS or Number Keys to move the cur-sor from one selection t

Página 9

Chapter 8. Telnet/Terminal Menus8-4 TSU 120 User Manual 61202129L1-1Editing the Temp MapTo edit the Temp Map, follow these steps.Applying the Temp Map

Página 10 - Interference Statement

Chapter 8. Telnet/Terminal Menus61202129L1-1 TSU 120 User Manual 8-5Remote Menu AccessThis displays TELNET menus for a remote device (may be another T

Página 11

Chapter 8. Telnet/Terminal Menus8-6 TSU 120 User Manual 61202129L1-1Figure 8-3. Unit Access TableAdd New UnitThis adds a new device to the unit acces

Página 12 - LIMITED PRODUCT WARRANTY

Chapter 8. Telnet/Terminal Menus61202129L1-1 TSU 120 User Manual 8-7Modify UnitAllows UNIT ID, PASSCODE, DEVICE TYPE, and POLLED FLAG to be changed fo

Página 13

xiCanadian Equipment LimitationsNotice: The Canadian Industry and Science Canada label identifies certified equipment. This certification means that t

Página 14

Chapter 8. Telnet/Terminal Menus8-8 TSU 120 User Manual 61202129L1-1To access other units external to the TSU 120 (proxied units) us-ing an SNMP MIB b

Página 15 - Training Fax (256) 963-6700

Chapter 8. Telnet/Terminal Menus61202129L1-1 TSU 120 User Manual 8-9System LocationA text string describing the physical location of an SNMP man-aged

Página 16

Chapter 8. Telnet/Terminal Menus8-10 TSU 120 User Manual 61202129L1-1Flash DownloadThe TSU 120 uses flash memory that allows software updates via the

Página 17 - Table of Contents

Chapter 8. Telnet/Terminal Menus61202129L1-1 TSU 120 User Manual 8-11TFTP Server File name: T120e.bizEnter the name of the upgrade file that resides o

Página 18

Chapter 8. Telnet/Terminal Menus8-12 TSU 120 User Manual 61202129L1-1

Página 19

61202029L1-1 TSU 120 User Manual A-1Appendix AUnderstanding SNMPABOUT SNMPAs local area network (LAN) environments became standard-ized over the past

Página 20

Appendix A. Understanding SNMPA-2 TSU 120 User Manual 61202029L1-1MIBThis is an index to the organized data within a network device. It defines the o

Página 21

Appendix A. Understanding SNMP61202029L1-1 TSU 120 User Manual A-3Trap This is an unsolicited message issued by a network device to report an operatio

Página 22

Appendix A. Understanding SNMPA-4 TSU 120 User Manual 61202029L1-1SNMP Trap ConfigurationTraps received by the TSU 120 from external units and the hos

Página 23 - List of Figures

Appendix A. Understanding SNMP61202029L1-1 TSU 120 User Manual A-5SNMP MIB BROWSER CONFIGURATIONThe following steps, shown in Ta ble A -1 are require

Página 24

xiiWarranty and Customer ServiceADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its publish

Página 25 - List of Tables

Appendix A. Understanding SNMPA-6 TSU 120 User Manual 61202029L1-1SNMP MIB Files Supported by the TSU 120Standard MIBs ADTRAN Enterprise-specific MIBs

Página 26

612020129L1-1 TSU 120 User Manual B-1Appendix B Understanding TR-08The TSU 120 chassis functions as a Remote Terminal in Digital Loop Carrier and as I

Página 27 - Introduction

Appendix B. Understanding TR-08B-2 TSU 120 User Manual 612020129L1-1Table B-1 explains what conditions trigger alarms and how alarms are processed wh

Página 28 - Chapter 1. Introduction

Appendix B. Understanding TR-08612020129L1-1 TSU 120 User Manual B-3TR-08 DS0 Conversion TableTable B-2 contains the mapping conversions needed to ma

Página 29 - TSU Option Modules

Appendix B. Understanding TR-08B-4 TSU 120 User Manual 612020129L1-1

Página 30

61202129L1-1 TSU 120 User Manual C-1Appendix CNetwork PinoutsWIRINGNetwork PinoutsOn the rear panel of the TSU 120 is an eight-position modular jack l

Página 31 - Installation

Appendix C. Network PinoutsC-2 TSU 120 User Manual 61202129L1-1Control In/Chain InThis is used as an EIA-232 port for connection to a computer or mode

Página 32 - GROUNDING INSTRUCTIONS

Appendix C. Network Pinouts61202129L1-1 TSU 120 User Manual C-3Chain OutThis is used to connect to another TSU 120 chain-in connector. See Table C-3 f

Página 33 - Chapter 2. Installation

Appendix C. Network PinoutsC-4 TSU 120 User Manual 61202129L1-1Nx56/64 DTE (V.35)See Table C-4 for the V.35 pinout Nx56/64 DTE pinout.ConnectionsThe D

Página 34

Appendix C. Network Pinouts61202129L1-1 TSU 120 User Manual C-5Base DSX-1 (PBX)See Tab le C- 5 for Base DSX-1 pinout connections for either-posi-tion

Página 35 - TSU 120 Interfaces

xiiiIn no event will ADTRAN or its suppliers be liable to Customer for any incidental, special, punitive, exemplary or consequential damages experienc

Página 36 - T-MON test jack

Appendix C. Network PinoutsC-6 TSU 120 User Manual 61202129L1-110BaseT (TSU 120e only)10BaseT is used to connect the TSU 120e to the local area net-wo

Página 37 - Initialization

61202129L1-1 TSU 120 User Manual D-1Appendix DSystem MessagesThis appendix lists and defines the alarm and status messages that appear on the TSU 120

Página 38

Appendix D. System MessagesD-2 TSU 120 User Manual 61202129L1-1DSX-1 (PBX) InterfaceThe following messages indicate a condition on the Base DSX-1 (PBX

Página 39 - Power-Up Procedure

Appendix D. System Messages61202129L1-1 TSU 120 User Manual D-3Nx56/64 InterfaceThe following messages indicate the status of the Nx56/64 card:DSX-1 (

Página 40

Appendix D. System MessagesD-4 TSU 120 User Manual 61202129L1-1

Página 41 - Operation

61202129L1-1 TSU 120 User Manual E-1Appendix ESpecificationsELECTRICAL SPECIFICATIONST1/FT1 InterfaceCompatibilityT1 Line Rate 1.544 Mbits/s +/- 75bp

Página 42 - CSU Status

Appendix E. SpecificationsE-2 TSU 120 User Manual 61202129L1-1Nx56/64 (V.35 Interface)DSX-1 InterfaceDCE Interface CCITT V.35 SynchronousRates 56kbps

Página 43 - Chapter 3. Operation

Appendix E. Specifications61202129L1-1 TSU 120 User Manual E-3MANAGEMENT INTERFACESChain In/Out Ports10BaseT Interface (TSU 120e only)Option Slot Inte

Página 44 - Shift+8

Appendix E. SpecificationsE-4 TSU 120 User Manual 61202129L1-1Environmental SpecificationsInput Power 90-120VAC, 47-63 HzFuse 0.6A, 250VOperating Temp

Página 45 - Down arrows

61202129L1-1 TSU 120e User Manual Index-1IndexSymbols.2 DSX-1 Port Configuration (PortConfig) Menu Items 5-23Numerics0.1 Nx56/64 Menu Items 4-50.1 Nx5

Página 46

xivCustomer Service, Product Support Information, and TrainingADTRAN will replace or repair this product within five years from the date of shipment i

Página 47 - Display Field

IndexIndex-2 TSU 120e User Manual 61202129L1-1DSU DP, option module 1-3DSU/DSX Status LEDs 3-4DSX-1 (PBX) Interface 2-6DSX-1 (PBX) Interface, systemm

Página 48 - Data Port Identification

Index61202129L1-1 TSU 120e User Manual Index-3Network Manager MIB, how toconfigure A-5Network Manager, SNMP componentA-1network menu items, configura

Página 49 - Front Panel Menu Structure

IndexIndex-4 TSU 120e User Manual 61202129L1-1SetRequest, SNMP command A-2SNMP MIB Browser Configuration A-5SNMP Read Community 8-7SNMP Read/Write Co

Página 50 - Alternate Methods of Control

xvIdentify the RMA number clearly on the package (below address), and return to the following address:ADTRAN Customer and Product Service901 Explorer

Página 52 - <CTRL> PTT

61202129L1-1 TSU 120 User Manual xviiTable of ContentsChapter 1 Introduction ...

Página 53

Table of Contentsxviii TSU 120 User Manual 61202129L1-1Power-Up Procedure ...

Página 54

Table of Contents61202129L1-1 TSU 120 User Manual xixDBU Status (TSU 120e only) ... 4-60.2 DSX-1 M

Página 55 - Status Menu

Trademarks:Windows is a registered trademark of Microsoft Corp.T-WATCH Pro is a trademark of ADTRAN, Inc.OpenView® is a trademark of Hewlett Packard

Página 56 - Clear (Shift+9)

Table of Contentsxx TSU 120 User Manual 61202129L1-1ENET Address (TSU 120e only) ...

Página 57 - Active Alarms

Table of Contents61202129L1-1 TSU 120 User Manual xxiManagement Configuration ...

Página 58 - Port Status

Table of Contentsxxii TSU 120 User Manual 61202129L1-1

Página 59

61202129L1-1 TSU 120 User Manual xxiiiList of FiguresFigure 1-1. TSU Option Modules ...

Página 60

xxiv TSU 120 User Manual 61202129L1-1List of Figures

Página 61 - ENET Status (TSU 120e only)

61202129L1-1 TSU 120 User Manual xxvList of TablesTable 3-1. Front Panel Descriptions ...

Página 62

List of Tablesxxvi TSU 120 User Manual 61202129L1-1

Página 63 - Configuration Menu

61202129L1-1 TSU 120 User Manual 1-1Chapter 1IntroductionTSU 120 OVERVIEWThis manual covers the use of the following products:•TSU 120• TSU 120eUnless

Página 64 - Chapter 5. Configuration Menu

Chapter 1. Introduction1-2 TSU 120 User Manual 61202129L1-1The TSU 120 offers a wide variety of network management options. You can manage via SNMP th

Página 65 - Network (NI) Menu Items

Chapter 1. Introduction61202129L1-1 TSU 120 User Manual 1-3• Integrated Dial Backup Capability in the Base Nx56/64 port ( TSU 120e only) • Extensive s

Página 66

iiiNotes provide additional useful information.Cautions signify information that could prevent service inter-ruption.Warnings provide information that

Página 67 - TSU 120 Clock Sources

Chapter 1. Introduction1-4 TSU 120 User Manual 61202129L1-1Option Module ArchitectureThe TSU 120 features a unique architecture that allows you to add

Página 68

61202129L1-1 TSU 120 User Manual 2-1Chapter 2InstallationUNPACK, INSPECT, POWER UPReceipt InspectionCarefully inspect the TSU 120 for any shipping dam

Página 69 - See Figure 5-3

Chapter 2. Installation2-2 TSU 120 User Manual 61202129L1-1Power ConnectionEach TSU 120 is equipped with a captive eight-foot power cord, terminated b

Página 70 - (OPTION)

Chapter 2. Installation61202129L1-1 TSU 120 User Manual 2-3mentary equipment grounding conductor shall be in compli-ance with the rules for terminatin

Página 71

Chapter 2. Installation2-4 TSU 120 User Manual 61202129L1-1Identification of Rear Panel LayoutThe configuration of the rear panel of the TSU 120e is s

Página 72

Chapter 2. Installation61202129L1-1 TSU 120 User Manual 2-5TSU 120 InterfacesThe TSU 120 is equipped with a Nx56/64 data port, a DSX-1 interface, an o

Página 73

Chapter 2. Installation2-6 TSU 120 User Manual 61202129L1-1DSX-1 (PBX) InterfaceThe DSX-1 Interface provides a short haul T1 for a PBX or other equipm

Página 74 - Unit Menu

Chapter 2. Installation61202129L1-1 TSU 120 User Manual 2-7Power Up TestingWhen shipped from the factory, the TSU 120 is set to factory default condit

Página 75

Chapter 2. Installation2-8 TSU 120 User Manual 61202129L1-1Set Chain Port InputThe TSU 120 can be configured from the chain port input when T-WATCH Pr

Página 76 - Map In Use: A(B)

Chapter 2. Installation61202129L1-1 TSU 120 User Manual 2-9At this point, the Unit Initialization procedure is concluded. If the unit is to be config

Página 77 - MAP A MAP B

ivAffidavit Requirements for Connection to Digital Services• An affidavit is required to be given to the telephone company whenever digital terminal e

Página 78

Chapter 2. Installation2-10 TSU 120 User Manual 61202129L1-1

Página 79 - Select Port

61202129L1-1 TSU 120 User Manual 3-1Chapter 3OperationFRONT PANELThe TSU 120 front panel monitors operation and controls the configuration of the unit

Página 80

Chapter 3. Operation3-2 TSU 120 User Manual 61202129L1-1LED DescriptionsCSU StatusThe CSU status LEDs display the operational condition of the network

Página 81

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-3.Figure 3-1. TSU 120 Front Panel LayoutNo Description Action/Status1 LCD Window Displays menu

Página 82 - EXTERNAL

Chapter 3. Operation3-4 TSU 120 User Manual 61202129L1-1DSU/DSX StatusThe DSU/DSX status LEDs display the operational condition of the Nx56/64 and DSX

Página 83 - Menu Items Description

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-5Operation Keys General Menu OperationThe TSU 120 uses a multilevel menu structure containing b

Página 84

Chapter 3. Operation3-6 TSU 120 User Manual 61202129L1-1Select and Activate a Menu ItemTo choose menu items, place the cursor on the desired menu item

Página 85

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-7Set the Data FieldYou can edit data fields preceded by a colon (:). Display Only Data Fiel

Página 86

Chapter 3. Operation3-8 TSU 120 User Manual 61202129L1-1The equal symbol after LBO in the second line indicates the information that follows is displa

Página 87 - Utility Menu

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-9Front Panel Menu StructureThe TSU 120 uses a multilevel menu structure containing both menu it

Página 88 - Chapter 6. Utility Menu

vAffidavit for Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital ServicesFor the work to be performed in the certified te

Página 89 - Time/Date

Chapter 3. Operation3-10 TSU 120 User Manual 61202129L1-1Alternate Methods of ControlT-WATCH Pro (ADTRAN PC Program)T-WATCH Pro is the ADTRAN PC contr

Página 90

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-11T-WATCH Pro/EIA-232 ConnectionTo set up the TSU 120e to work with T-WATCH Pro over a direct E

Página 91 - CMD Mode

Chapter 3. Operation3-12 TSU 120 User Manual 61202129L1-1 To use SNMP via SLIP port, follow these steps:Terminal ModeThe TSU 120 provides the front pa

Página 92

Chapter 3. Operation61202129L1-1 TSU 120 User Manual 3-13N-Form support is only available for the TSU 120e.N-FormThe TSU 120e can also be controlled v

Página 93 - Test Menu

Chapter 3. Operation3-14 TSU 120 User Manual 61202129L1-1

Página 94

61202129L1-1 TSU 120 User Manual 4-1Chapter 4Status MenuThe Status menu branch provides the ability to view the status of the TSU 120 operation. See F

Página 95 - Network Tests

Chapter 4. Status Menu4-2 TSU 120 User Manual 61202129L1-1Network Performance Reports (NI PERF RPTS)The Network Interface Performance Reports display

Página 96

Chapter 4. Status Menu61202129L1-1 TSU 120 User Manual 4-3Since only the user’s copy of performance data is cleared by the TSU 120, the data displayed

Página 97

Chapter 4. Status Menu4-4 TSU 120 User Manual 61202129L1-1Figure 4-3. Display of Alarm MessageView HistoryThis menu item both displays and clears the

Página 98 - QRSS ALL DS0S

Chapter 4. Status Menu61202129L1-1 TSU 120 User Manual 4-50.1 Nx56/64 Menu Items DTE Data/ClockAn asterisk (*) indicates an active status of the follo

Página 99 - Run Self-test

viI attest that the operator(s)/maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog

Página 100 - Port Tests

Chapter 4. Status Menu4-6 TSU 120 User Manual 61202129L1-1DBU Contrl (TSU 120e only)DBU Status (TSU 120e only)0.2 DSX-1 Menu ItemsDSX-1 Errors RTSRequ

Página 101 - Clear (Shift+9)

Chapter 4. Status Menu61202129L1-1 TSU 120 User Manual 4-7Remote PortRemote Port displays the status of activity on the control-in remote port. This i

Página 102 - Cancel Tests

Chapter 4. Status Menu4-8 TSU 120 User Manual 61202129L1-1

Página 103 - Telnet/Terminal Menus

61202129L1-1 TSU 120 User Manual 5-1Chapter 5Configuration MenuThe CONFIGURATION MENU sets the TSU 120 operational config-uration, including all netwo

Página 104

Chapter 5. Configuration Menu5-2 TSU 120 User Manual 61202129L1-1Figure 5-1. Complete Configuration Menu1) FORMAT 1) CTL PORT RATE2) CODE 2) TRAPS3)

Página 105

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-3NETWORK (NI)This menu item accesses the configuration of parameters asso-ciated with

Página 106

Chapter 5. Configuration Menu5-4 TSU 120 User Manual 61202129L1-1SET LBO Selects the line build out for the network interface. In AUTO MODE, the TSU 1

Página 107 - Remote Menu Access

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-5TSU 120 Clock SourcesThe TSU 120 is operable from various clock sources permitting it

Página 108

Chapter 5. Configuration Menu5-6 TSU 120 User Manual 61202129L1-1Network TimedThe network is the source of timing. The received data clocking is loope

Página 109

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-7Base DSX-1 TimingThe PBX is the source of timing. The TSU 120 uses the clock derived

Página 110

viiI agree to provide ______________________ (telco’s name) with proper documentation to demonstrate compliance with the information as provided in th

Página 111

Chapter 5. Configuration Menu5-8 TSU 120 User Manual 61202129L1-1DTE TimingThe DTE is the source of timing. The TSU 120 uses the incom-ing DTE clock t

Página 112 - Flash Download

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-9Internal TimingThe TSU 120 is the source of timing. The TSU 120 is configured to use

Página 113 - Quit Session

Chapter 5. Configuration Menu5-10 TSU 120 User Manual 61202129L1-1Secondary TimingThe secondary interface is the source of timing. The TSU 120 uses th

Página 114

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-11Normal (CSU) TimingIn the Normal (CSU) Timing mode, the Receive Clock is derived fro

Página 115 - Understanding SNMP

Chapter 5. Configuration Menu5-12 TSU 120 User Manual 61202129L1-1Unit MenuThe Unit menu changes the baud rate of the chain in port and the setup of t

Página 116 - Messages

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-13IP ADDRESS This is the IP address that uniquely identifies the TSU 120 on a TCP/IP n

Página 117 - TSU 120 SNMP Access

Chapter 5. Configuration Menu5-14 TSU 120 User Manual 61202129L1-1Map Exchange (Map Xchng) The MAP EXCHANGE menu enables and sets the automatic time

Página 118 - SNMP Trap Configuration

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-15DS0 Map A and DS0 Map BThe DS0 maps designate which DS0s are assigned to which port.

Página 119 - Step Action

Chapter 5. Configuration Menu5-16 TSU 120 User Manual 61202129L1-1DSO Map ExampleA sample selection follows:DS0: 01 to 24PORT: IDLE, TST, + option mo

Página 120

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-17With the cursor on CREATE TEMP, press Enter. The unit displays the selection screen

Página 121 - Understanding TR-08

viiiFCC regulations require that the following information be provided in this manual:1. This equipment complies with Part 68 of FCC rules. On the bac

Página 122 - Table B-1

Chapter 5. Configuration Menu5-18 TSU 120 User Manual 61202129L1-1 Port Configuration (Port Config)Port Configuration selects and configures the param

Página 123 - TR-08 DS0 Conversion Table

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-19DATA Used to control the inverting of the DTE data. This inversion can be useful whe

Página 124

Chapter 5. Configuration Menu5-20 TSU 120 User Manual 61202129L1-1Table 5-1. Normal Mode of OperationINBAND MODE The Nx56/64 port is capable of prov

Página 125 - Network Pinouts

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-21DBU Configuration Menu Items (TSU 120e only) Menu Items DescriptionBACKUP MODE In a

Página 126 - Control In/Chain In

Chapter 5. Configuration Menu5-22 TSU 120 User Manual 61202129L1-1RESTORE DELAY Selects the time that elapses between the network going out of alarm o

Página 127 - Chain Out

Chapter 5. Configuration Menu61202129L1-1 TSU 120 User Manual 5-230.2 DSX-1 Port Configuration (Port Config) Menu ItemsThe menu items are:ENABLE HR Th

Página 128 - Nx56/64 DTE (V.35)

Chapter 5. Configuration Menu5-24 TSU 120 User Manual 61202129L1-1LINE LENGTH (FT) LINE LENGTH provides selection of the proper output level for the b

Página 129 - Base DSX-1 (PBX)

61202129L1-1 TSU 120 User Manual 6-1Chapter 6Utility MenuThe UTILITY MENU tree displays and sets system parameters (see Figure 6-1 on page 6-2). This

Página 130 - 10BaseT (TSU 120e only)

Chapter 6. Utility Menu6-2 TSU 120 User Manual 61202129L1-1Figure 6-1. Complete Utility Menu TreeTIME: HH:MM:SS1) TIME/DATE DATE: MM/DD/YY(Returns al

Página 131 - System Messages

Chapter 6. Utility Menu61202129L1-1 TSU 120 User Manual 6-3Time/DateThis menu option displays or edits the current time and date. The TSU 120 maintain

Página 132 - Status Messages

ix8. The REN is useful in determining the quantity of devices you may connect to your telephone line and still have all of those devices ring when you

Página 133

Chapter 6. Utility Menu6-4 TSU 120 User Manual 61202129L1-1Pressing any key after entering a passcode causes the unit to return to the previous active

Página 134 - Appendix D. System Messages

Chapter 6. Utility Menu61202129L1-1 TSU 120 User Manual 6-5If an out-of-range number is entered, the unit assumes the upper limit number of 999.Set th

Página 135 - Specifications

Chapter 6. Utility Menu6-6 TSU 120 User Manual 61202129L1-1

Página 136 - Appendix E. Specifications

61202129L1-1 TSU 120 User Manual 7-1Chapter 7Test MenuThe TEST MENU initiates different types of unit tests and dis-plays test results in the LCD wind

Página 137 - Chassis Specifications

Chapter 7. Test Menu7-2 TSU 120 User Manual 61202129L1-1Figure 7-1. Complete Test Menu TreeLINE ON1) LOCAL LOOPBCK PAYLOAD ONNO LOOPBACK ATT INBAND L

Página 138 - Environmental Specifications

Chapter 7. Test Menu61202129L1-1 TSU 120 User Manual 7-3Network TestsNetwork tests control the activation of loopbacks and the initia-tion of data tes

Página 139

Chapter 7. Test Menu7-4 TSU 120 User Manual 61202129L1-1Figure 7-2. Network Loopback TestsLOCAL LOOPBCKThere are three available choices for setting

Página 140

Chapter 7. Test Menu61202129L1-1 TSU 120 User Manual 7-5Remote Loopback can only be used with Fractional T1 if the ANSI FT1 LLB is selected.After a Re

Página 141

Chapter 7. Test Menu7-6 TSU 120 User Manual 61202129L1-1QRSS always runs at 64K/DS0.Example1. Select QRSS ALL DS0S by using the Arrow Keys. 2. Press E

Página 142

Chapter 7. Test Menu61202129L1-1 TSU 120 User Manual 7-7Press Shift+9 to clear results. The results are accumulated until the test pattern is set to N

Comentários a estes Manuais

Sem comentários