ADTRAN 1200214L1 Especificações Página 135

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 176
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 134
Chapter 10. Statistics
61200214L1-20 IQ Probe User Manual 10-31
DBU Port Statistics Available on Front Panel
DBU statistics are only available if a dial backup card is installed.
DBU Status
Current state of the DBU circuit.
Time in DBU
The amount of time (in seconds) that the unit has been in dial backup
mode.
Frames In
Total received frames since the unit went into dial backup mode (or since
last reset).
Frames Out
Total transmitted frames since the unit went into dial backup mode (or
since last reset).
Errored Frames
Total errored frames received since the unit went into dial backup mode
(or since last reset).
CRC Errors
Number of frames received on the dial backup circuit with CRC viola-
tions.
Abort Frames
Total frames received on the dial backup circuit without a closing flag.
Octet Align
Number of frames received on the dial backup circuit with a bit count that
does not fall on 8-bit boundaries.
Vista de página 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 175 176

Comentários a estes Manuais

Sem comentários