61200.175L1-1 FSU 5622 ESP User Manual 85
Chapter 8. Configuring the Network Port
Signaling Type (SIGNAL)
Set the signaling type option to match the network signaling
type.
For point-to-point DDS operation, signalling should be set to NONE.
T391
Set the time between polls to the frame relay network.
N391
Determine how many link integrity polls occur in between full
status polls.
N392 and N393
These parameters define the error threshold for the UNI formed
by the FSU 5622 ESP network port and the frame relay switch. If
the error threshold is met, the signaling state status is changed to
down, which indicates a service-affecting condition. This
condition is cleared once N393 consecutive error-free events are
received. N392 defines the number of errors required in a given
event window, while N393 defines the number of polling events
in each window.
For example:
If N392=3 and N393= 4, then if three errors occur within any four
events the interface is determined inactive.
The status of the connection can be viewed in the Status menu
under Network Port Signaling State. The status will return to
active again once the threshold is no longer exceeded.
Remote FECN Notification (RFECN)
Enable/disable the FSU 5622 ESP to issue remote FECN (for-
ward explicit congestion notification). This feature ensures that
a frame will be generated in the reverse direction upon receiving
a frame with the FECN bit enabled. This is a proprietary feature
with ADTRAN FSU 5622 ESPs and can only be used with an
ADTRAN FSU 5622 ESP on both ends of the virtual circuit.
The network service provider should recommend the values entered into
the T391, N391, N392, and N393 fields.