ADTRAN 1204006L1 Manual do Utilizador Página 77

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 175
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 76
61200.175L1-1 FSU 5622 ESP User Manual 61
Chapter 6. DTE Port Configuration
Bisync Protocol
The Bisync protocol option enables the FSU 5622 ESP to connect
IBM 2780/3780 bisync controllers to the host across frame relay.
Both point-to-point and multi-point configurations are sup-
ported.
The FSU 5622 ESP can decode both ASCII and EBCDIC character
sets and support CRC16, parity, VRC, and LRC error checking
methods. See Figure 6-7 for the Bisync protocol menu tree.
1 PROTOCOL 5 BISYNC
1 DTE PORT 1
2 PHYSICAL LAYER OPTIONS 1 INTERFACE TYPE 1 EIA 232
1 CONFIG 2 V.35
2 DTE PORT 2 1 2400 bps
2 SYNCHRONOUS BIT RATE 2 4800 bps
3 9600 bps
4 19.2 Kbps
5 38400 bps
6 56000 bps
7 64000 bps
3 TRANSMIT IDLE CODE 1 FLAGS
2 ONES
4 HARDWARE FLOW CONTROL 1 OFF
2 ON
1 PRIMARY
3 PROTOCOL OPTIONS 1 EMULATION TYPE 2 SECONDARY
2 LINE TYPE 1 POINT-TO-POINT
2 MULTIPOINT
3 TRANSLATION CODE 1 EBCDIC CRC 16
2 ASCII CRC16
2 ASCII ODD PARITY VRC, LRC
3 ASCII EVEN PARITY VRC, LRC
4 DATA FORMAT 1 NRZ
5 POLL/RESPONSE TIMEOUT 2 NRZI
6 DISCONNECT THRESHOLD
7 SLOW POLL RATIO <N:1> 1 FOLLOW RTS
8 CTS OPTION 2 FORCED ON
4 PROTOCOL ADDRESS TABLE 1 UNIT ADDRESS
2 LLC2 SSAP
3 LLC2 DSAP
4 OUTGOING DLCI
Figure 6-7
Bisync Protocol Menu Tree
Vista de página 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 174 175

Comentários a estes Manuais