92 FSU 5622 ESP User Manual 61200.175L1-1
Chapter 9. Configuring Dial Backup Options
With No Receive (RX) Signal
When enabled, the FSU 5622 ESP enters backup mode when a
loss of signal is detected. The factory default setting is Enable.
With No Sealing Current
When enabled, the FSU 5622 ESP enters backup mode when a
loss of sealing current is detected. The factory default setting is
Enable.
DBU Timers
Fail Timer
This option sets the amount of time the dedicated circuit failure
condition must be active before the FSU 5622 ESP attempts
backup. The amount of time, which is manually entered, can be
up to 990 seconds. The factory default setting is 30 seconds.
AUTO DBU FAIL
TIME: __ __ x 10sec
Restore Timer
Once the DDS circuit is down, the FSU 5622 ESP remains in
backup until the DDS circuit is active for the length of time
specified for the restore timer. The selection is entered in min-
utes (up to 255). If set to 0, the DDS must be restored manually.
The factory default setting is 1 minute.
RESTORE TIMER
(0=OFF): __ __ MIN
Redial Counter
This option sets the number of times the FSU 5622 ESP re-dials
the far end when entering backup mode. The redial count,
which is manually entered, can be up to a maximum of 99
attempts. If the FSU 5622 ESP encounters a busy or reorder, it
attempts to establish the call the specified number of times. The
factory default setting is 5.