ADTRAN TA 544 Manual de Instruções Página 147

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 162
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 146
Total Access 544R System Manual Section 5 DLP-15
61200704L2-1B © 2003 ADTRAN, Inc. 147
Upgrade From A.03 to A.03.9X (Transition Build) to A.04
1. Upgrade the firmware from A.03 to A.03.9X (Transition Build) firmware. See DLP-7 or DLP-8 for
instructions on how to perform this upgrade.
2. Once the upgrade to A.03.9X is complete, immediately upgrade the unit to A.04. See
DLP-7 or DLP-8 for instructions on how to perform this upgrade.
Upgrade From A.03 to A.04 Directly
1. Upgrade the firmware from A.03 to A.04 firmware. See DLP-7 or DLP-8 for instructions on how to
perform this upgrade.
2. The unit must then be factory defaulted: by one of the following methods:
Select SYSTEM UTILITY > TERMINAL MODE. At the > prompt, type fac. You will then see “Restore
Factory Defaults and Reset Unit? (press 'y').” Press the Y key to confirm default. The unit will then
automatically reset.
If connected to the
CRAFT port, power reset the unit and then restore power to the unit while
holding down the F key. You will then be prompted to confirm the factory default.
3. Reconfigure the unit for the specific application.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
Perform Steps Below in the Order Listed
Upgrading from A.03 to A.03.9X (Transition Build) to A.04 will save the unit's
configuration.
Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit's
configuration.
Vista de página 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 161 162

Comentários a estes Manuais

Sem comentários